CASE STUDY | Incident Response & Data Center Stabilization

From Firefighting to Stability

How Nubius Solutions helped a customer recover from a data center-wide outage and take back control of a fragmented infrastructure.

20 min

to restore a failed application after 2–3 hours of internal attempts

Minutes

to recover a Kubernetes cluster that had been down 10+ hours

1 month

standby support following the outage

1

incident room replacing fragmented calls, chats and recovery attempts

10

foundational risks documented in the post-incident review

12–17 hrs

of downtime across VMware, core components and Kubernetes in one outage

Customer: A fast-growing SaaS provider. The customer’s platform delivers emergency texts, storm notifications and outage updates for utilities and critical public services.

Environment: Two on-premises data centers plus AWS, GCP and private cloud, running VMware, Kubernetes, Proxmox and Docker Swarm. Ongoing acquisitions required continuous integration of new systems and applications.

How it started: Nubius was engaged for a post-acquisition Google Workspace to Microsoft 365 migration. Infrastructure was not in scope.

Nubius role: Emergency incident response, layer-by-layer stabilization, post-incident review, on-call standby, and a full infrastructure assessment.

When the Platform Goes Down, So Go the Alerts

This company’s platform is used by utilities to reach the public when it matters most: enabling storm warnings, outage updates and emergency notifications. During major weather events it becomes part of the utilities’ critical operations. An outage is not just downtime. Messages that need to go out don’t.

During a global Cloudflare outage, the company’s systems started failing. Cloudflare affected external DNS, but the internal failures went far beyond it. The entire data center was affected. VMware was down for 12 hours, other components for up to 14 hours, and the Kubernetes cluster for 17. The cost went far beyond downtime: executive and engineering time, support escalations, delayed notifications, missed SLAs and strained relationships with high-value utility customers.

The Challenge

The company had grown fast, much of it through acquisitions. Its infrastructure had grown with it, but visibility, documentation and standards had not kept up:

  • A fragmented architecture: two data centers, three clouds and four orchestration platforms, with inconsistent standards and naming.
  • No source of truth: no dependency mapping, no runbooks, and monitoring that was incomplete or misleading on critical paths.
  • Hidden single points of failure: hardcoded dependencies, such as Vault tied to a single on-premises VM, and databases running where they did not belong.
  • Aging network gear: end-of-life switches with logging disabled, which left no trail when things broke.
  • Knowledge in too few hands: only a handful of engineers understood parts of the infrastructure, and no one had the full picture.

How Nubius Delivered

Nubius was not engaged to run this infrastructure. Nubius was brought in initially to address a serious outage. The relationship grew one stage at a time, each one earned by results.

Stage 1 — First contact: trust built in 20 minutes

Early in the Microsoft 365 project, one of the company’s applications went down. Internal teams spent two to three hours trying to recover a broken Docker Swarm environment. Because Nubius had already helped with a MongoDB migration, the issue was escalated to Nubius, which had no prior knowledge of these systems.

Nubius found a misconfigured Swarm cluster, NAS connectivity issues, and earlier restart attempts that had made things worse. Within 20 minutes, the cluster was stable and the application was back. Leadership saw rapid, structured, end-to-end troubleshooting, and it set up what came next.

Stage 2 — The breaking point: a data center-wide outage

Weeks later, the Cloudflare outage hit and internal issues cascaded. Multiple applications went down and alerts fired across separate monitoring systems. There was no single incident room, and teams split across several calls and chats. Recovery attempts conflicted with each other, and there was no view of dependencies or structured process to follow. For hours, the response stayed reactive while leadership, up to the CEO, joined the war room.

Stage 3 — Taking command: structure before fixes

Once Nubius was brought in with elevated access, the first change was structural. Nubius set up a single incident room, built a prioritized list of critical services, tracked recovery progress, and set a clear order: infrastructure first, then platforms, then applications.

Validating the infrastructure turned up the real problems. There were issues with recently added switches and NAS connectivity, end-of-life switches with logging disabled, and VMware storage rescans that had not been done correctly. Earlier rollbacks had used up hours without touching the actual cause.

Stage 4 — Layer-by-layer stabilization

With a clear picture, recovery moved fast:

  • Virtualization: ESXi nodes revalidated, storage path issues corrected, and essential VMs restarted, so the hosts were healthy before any work on applications.
  • Kubernetes: the cluster had been down for more than ten hours, and repeated restarts kept failing. The root cause was a configuration that always started from a corrupted primary node. Once Nubius directed the correct recovery steps, the cluster came back within minutes, and nodes and containers followed.
  • Applications: critical services came back progressively on top of a now-stable foundation.

Stage 5 — Post-incident review: symptoms, not accidents

Nubius’s post-mortem showed the outage was not an isolated event but the result of systemic issues: no source of truth or dependency mapping, misconfigured virtualization, Kubernetes misconfiguration and misplaced workloads, hardcoded paths, no runbooks, monitoring gaps, end-of-life network gear, and reliance on a few individuals with partial knowledge.

Nubius’s key message to leadership: hiring more engineers would not fix it. Without clarity, new staff would be set up to fail.

Stage 6 — Standby and the path forward

The company then kept Nubius on standby for the following month. During that time, Nubius reverse-engineered applications and subsystems, documented the architectural issues, and moved MongoDB out of Kubernetes after a later failure. Nubius also acted as the bridge between internal teams and flagged further risks for correction.

Then came the larger decision. The company chose Nubius for a full infrastructure assessment over other options, including a Kubernetes-focused partner and AWS professional services. The deciding factors were trust, transparency, direct communication, and a partner that would stay engaged through execution, not just hand over recommendations.

The Results

The standby results were achieved before the full assessment began. This gave the customer a stable foundation to modernize from.

The assessment led to a plan to replace VMware and its QNAP storage with OpenNebula and StorPool. Nubius designed and implemented the new platform and continues to help the customer migrate workloads from VMware.

BeforeAfter
Incident responseTeams split across multiple calls and chats; conflicting recovery attemptsA single incident room, a prioritized list of critical services, and tracked recovery progress
Recovery approachRollbacks and restarts that used up time and made some issues worseOrdered recovery: infrastructure first, then platforms, then applications, validated at each layer
VisibilityNo source of truth, no dependency map, monitoring gaps on critical pathsApplications and subsystems reverse-engineered and documented; architectural risks identified
KnowledgeConcentrated in a few people, each with a partial viewDocumented architecture; Nubius bridging coordination between internal teams
ArchitectureMongoDB running inside Kubernetes; hardcoded dependencies hiding single points of failureMongoDB moved out of Kubernetes; remaining risks documented for correction
Major outagesRecurring, including a data center-wide outage of 12 to 17 hours depending on the platformNo further major outages during the standby period

The Bigger Picture

Fast-growing companies, especially ones that grow through acquisitions, often add systems faster than they add visibility. Fragmented monitoring, architectural drift, missing runbooks and knowledge concentrated in a few people create the conditions for a small incident to become a prolonged, costly outage.

Nubius brings what those moments need: calm, structured command in a crisis, an honest diagnosis of root causes, and the commitment to stay through the fix.